10
LTC1608
(CONVST =
)
Figure 5. Mode 1a. CONVST Starts a Conversion. Data Outputs Always Enabled
DATA N
D15 TO D0
DATA (N + 1)
D15 TO D0
DATA (N – 1)
D15 TO D0
CONVST
CS = RD = 0
BUSY
1608 F05
t5
tCONV
t6
t8
t7
DATA
Figure 7. Mode 2. CONVST Starts a Conversion. Data is Read by RD
CONVST
CS = 0
BUSY
1608 F07
t5
tCONV
t8
t13
t6
t9
t12
DATA N
D15 TO D0
t11
t10
RD
DATA
DATA (N – 1)
D15 TO D0
CONVST
BUSY
1608 F06
tCONV
t6
t13
t7
CS = RD = 0
DATA N
D15 TO D0
DATA (N + 1)
D15 TO D0
DATA
t5
t6
t8
Figure 6. Mode 1b. CONVST Starts a Conversion. Data Outputs Always Enabled
(CONVST =
)
APPLICATIO S I FOR ATIO
WU
UU